Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 586
Filtrar
1.
Chest ; 160(3): e295-e298, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34488971

RESUMO

CASE PRESENTATION: A 64-year-old man with a past medical history of alcoholic cirrhosis with resultant hepatorenal syndrome requiring kidney and liver transplantation 10 years previously sought treatment at the ED with progressive lower-extremity edema and dyspnea. After noting worsening shortness of breath and cough as an outpatient, he had been referred to a pulmonary clinic and was undergoing a workup for interstitial lung disease (ILD). He had been started on prednisone 40 mg/d after a lung biopsy 4 months before admission. He was also receiving chronic immunosuppression with tacrolimus and mycophenolate mofetil. He had noted worsening of edema since starting prednisone.


Assuntos
Aminoacil-tRNA Sintetases/imunologia , Autoanticorpos/sangue , Insuficiência Cardíaca , Imunossupressores/administração & dosagem , Doenças Pulmonares Intersticiais , Miosite , Hipertensão Arterial Pulmonar , Diagnóstico Diferencial , Dispneia/diagnóstico , Dispneia/etiologia , Ecocardiografia/métodos , Edema , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Humanos , Veias Jugulares/fisiopatologia , Transplante de Rim/métodos , Transplante de Fígado/métodos , Doenças Pulmonares Intersticiais/imunologia , Doenças Pulmonares Intersticiais/patologia , Doenças Pulmonares Intersticiais/fisiopatologia , Masculino , Pessoa de Meia-Idade , Miosite/diagnóstico , Miosite/imunologia , Miosite/fisiopatologia , Miosite/terapia , Hipertensão Arterial Pulmonar/diagnóstico , Hipertensão Arterial Pulmonar/etiologia , Hipertensão Arterial Pulmonar/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Pressão Venosa
3.
AJR Am J Roentgenol ; 216(6): 1626-1633, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32876481

RESUMO

Dural arteriovenous fistulas (DAVFs) are high-flow acquired shunts that can carry high risk of intracranial hemorrhage. Because DAVFs can often be managed by endovascular means, early and accurate diagnosis can markedly improve patient morbidity. Time-of-flight and arterial spin-labeling MRA have increased the diagnostic utility of MRI for DAVF by showing hemodynamic rather than anatomic evidence of shunting. The purpose of this article is to describe the cases of seven patients who had co-localization of arterial spin-labeling signal intensity and time-of-flight flow-related enhancement in the left skull base, resulting in a misdiagnosis of DAVF and a recommendation for catheter angiography by the interpreting radiologist. Benign jugular venous reflux is identified as a common mechanism in each case, and the physiology behind this imaging pitfall is described. An algorithmic diagnostic approach to differentiating physiologic venous reflux from true posterior skull base DAVFs is presented.


Assuntos
Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Encéfalo/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/fisiopatologia , Diagnóstico Diferencial , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade
4.
Ann Pharmacother ; 55(5): 658-665, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32909436

RESUMO

OBJECTIVE: To determine the optimal anticoagulation strategy in patients diagnosed with Lemierre Syndrome (LS). DATA SOURCES: A systematic review in accordance with PRISMA guidelines was conducted using PubMed, MEDLINE, Scopus, ProQuest, and CINAHL from January to April 2020. Search terms included "Lemierre Syndrome" AND "anticoagulation" NOT "prophylaxis" OR "atrial fibrillation," in addition to a list of parenteral and oral anticoagulants. Adult patients who developed a clot and required systemic anticoagulation as a result of LS were included in this review. STUDY SELECTION AND DATA EXTRACTION: A total of 4180 records were initially identified, though following the removal of duplicates and nonrelevant entries, 216 full-text articles were reviewed for inclusion; 13 articles were ultimately included. DATA SYNTHESIS: The majority (11/14) of patients developed thromboses of the internal jugular veins, which corresponds to the pathophysiology of LS. Anticoagulation strategies were varied in the included literature, though 12/14 patients initially received a parenteral product. Two patients received a direct-acting oral anticoagulant (DOAC) following either intravenous heparin or subcutaneous enoxaparin and had outcomes similar to patients transitioned to warfarin. RELEVANCE TO PATIENT CARE AND CLINICAL PRACTICE: Anticoagulation in LS is a clinical controversy because the thromboembolic events have rarely led to significant complications; thrombi typically resolve independently, and concerns for bleeding risks are well founded; however, this review indicates both the efficacy and safety of anticoagulation. CONCLUSIONS: Anticoagulation is both efficacious and safe in LS, including treatment using a DOAC. Although further studies are needed, clinicians should consider a duration of anticoagulation of 6 to 12 weeks.


Assuntos
Anticoagulantes/administração & dosagem , Gerenciamento Clínico , Síndrome de Lemierre/tratamento farmacológico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Esquema de Medicação , Enoxaparina/administração & dosagem , Heparina/administração & dosagem , Humanos , Veias Jugulares/efeitos dos fármacos , Veias Jugulares/fisiopatologia , Síndrome de Lemierre/complicações , Síndrome de Lemierre/fisiopatologia , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Tromboembolia/tratamento farmacológico , Tromboembolia/etiologia , Tromboembolia/fisiopatologia , Varfarina/administração & dosagem
5.
J Neurosci Res ; 99(2): 423-445, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32981154

RESUMO

The purpose of this clinical trial was to examine whether internal jugular vein compression (JVC)-using an externally worn neck collar-modulated the relationships between differential head impact exposure levels and pre- to postseason changes in diffusion tensor imaging (DTI)-derived diffusivity and anisotropy metrics of white matter following a season of American tackle football. Male high-school athletes (n = 284) were prospectively assigned to a non-collar group or a collar group. Magnetic resonance imaging data were collected from participants pre- and postseason and head impact exposure was monitored by accelerometers during every practice and game throughout the competitive season. Athletes' accumulated head impact exposure was systematically thresholded based on the frequency of impacts of progressively higher magnitudes (10 g intervals between 20 to 150 g) and modeled with pre- to postseason changes in DTI measures of white matter as a function of JVC neck collar wear. The findings revealed that the JVC neck collar modulated the relationships between greater high-magnitude head impact exposure (110 to 140 g) and longitudinal changes to white matter, with each group showing associations that varied in directionality. Results also revealed that the JVC neck collar group partially preserved longitudinal changes in DTI metrics. Collectively, these data indicate that a JVC neck collar can provide a mechanistic response to the diffusion and anisotropic properties of brain white matter following the highly diverse exposure to repetitive head impacts in American tackle football. Clinicaltrials.gov: NCT# 04068883.


Assuntos
Lesões Encefálicas Traumáticas/prevenção & controle , Bandagens Compressivas , Futebol Americano/lesões , Traumatismos Cranianos Fechados/complicações , Veias Jugulares , Equipamentos de Proteção , Substância Branca/lesões , Esportes Juvenis/lesões , Acelerometria , Adolescente , Lesões Encefálicas Traumáticas/diagnóstico por imagem , Lesões Encefálicas Traumáticas/etiologia , Imagem de Tensor de Difusão , Desenho de Equipamento , Traumatismos Cranianos Fechados/epidemiologia , Humanos , Veias Jugulares/fisiopatologia , Masculino , Modelos Neurológicos , Cooperação do Paciente , Estudos Prospectivos , Recidiva , Estados Unidos , Substância Branca/diagnóstico por imagem , Substância Branca/patologia
7.
J Vis Exp ; (160)2020 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-32628153

RESUMO

Here we provide a detailed protocol describing the clinical procedure of hepatic venous pressure gradient (HVPG) measurement in patients with advanced chronic liver disease followed by an instruction for transjugular biopsy. Under local anesthesia and ultrasound guidance, a catheter introducer sheath is placed in the right internal jugular vein. Using fluoroscopic guidance, a balloon catheter is advanced into the inferior vena cava (IVC) and inserted into a large hepatic vein. Correct and sufficient wedge position of the catheter is ensured by injecting contrast media while the balloon is blocking the outflow of the cannulated hepatic vein. After calibrating the external pressure transducer, continuous pressure recordings are obtained with triplicate recordings of the wedged hepatic venous pressure (WHVP) and free hepatic venous pressure (FHVP). The difference between FHVP and WHVP is referred to as HVPG, with values ≥10 mm Hg indicating clinically significant portal hypertension (CSPH). Before removing the catheter, pressure readings obtained in the IVC at the same level, as well as the right atrial pressure are recorded. Finally, a transjugular liver biopsy can be obtained via the same vascular route. Different systems are available; however, core biopsy needles are preferred over aspiration needles, especially for cirrhotic livers. Again, under fluoroscopic guidance a biopsy needle introducer sheath is advanced into an hepatic vein. Next, the transjugular biopsy needle is gently advanced through the introducer sheath: (i) in case of aspiration biopsy, the needle is advanced into the liver parenchyma under aspiration and then removed quickly, or (ii) in case of a core biopsy, the cutting-mechanism is triggered inside the parenchyma. Several separate passages can be safely performed to obtain sufficient liver specimens via transjugular biopsy. In experienced hands, the combination of these procedures takes about 30-45 min.


Assuntos
Veias Hepáticas/fisiopatologia , Veias Jugulares/fisiopatologia , Fígado/patologia , Pressão Venosa/fisiologia , Biópsia , Cateteres , Feminino , Hemodinâmica , Humanos , Fígado/irrigação sanguínea , Fígado/fisiopatologia , Masculino
8.
Vascular ; 28(5): 664-672, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32390561

RESUMO

BACKGROUND: The high rate of clinical failure of prosthetic arteriovenous grafts continues to suggest the need for novel tissue-engineered vascular grafts. We tested the hypothesis that the decellularized rat jugular vein could be successfully used as a conduit and that it would support reendothelialization as well as adaptation to the arterial environment. MATERIALS AND METHODS: Autologous (control) or heterologous decellularized jugular vein (1 cm length, 1 mm diameter) was sewn between the inferior vena cava and aorta as an arteriovenous graft in Wistar rats. Rats were sacrificed on postoperative day 21 for examination. RESULTS: All rats survived, and grafts had 100% patency in both the control and decellularized groups. Both control and decellularized jugular vein grafts showed similar rates of reendothelialization, smooth muscle cell deposition, macrophage infiltration, and cell turnover. The outflow veins distal to the grafts showed similar adaptation to the arteriovenous flow. Both CD34, CD90 and nestin positive cells, as well as M1-type and M2-type macrophages accumulated around the graft. CONCLUSIONS: This model shows that decellularized vein can be successfully used as an arteriovenous graft between the rat aorta and the inferior vena cava. Several types of cells, including progenitor cells and macrophages, are present in the host response to these grafts in this model. This model can be used to test the application of arteriovenous grafts before conducting large animal experiments.


Assuntos
Aorta/cirurgia , Derivação Arteriovenosa Cirúrgica , Veias Jugulares/transplante , Grau de Desobstrução Vascular , Veia Cava Inferior/cirurgia , Animais , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Células Progenitoras Endoteliais/metabolismo , Células Progenitoras Endoteliais/patologia , Células-Tronco Hematopoéticas/metabolismo , Células-Tronco Hematopoéticas/patologia , Veias Jugulares/metabolismo , Veias Jugulares/patologia , Veias Jugulares/fisiopatologia , Macrófagos/metabolismo , Macrófagos/patologia , Masculino , Ratos Wistar , Fatores de Tempo , Remodelação Vascular
9.
Shock ; 54(6): 717-722, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32433209

RESUMO

BACKGROUND: Fluid resuscitation, which is critical to counter acute hemorrhagic shock, requires prompt and accurate intravascular volume estimation for optimal fluid administration. This study aimed to evaluate whether cardiac variation of internal jugular vein (IJV), evaluated by ultrasonography, could detect hypovolemic status and predict response to fluid resuscitation. METHODS: Patients undergoing autologous blood transfusion for elective surgery who were prospectively enrolled at the study blood donation center between August 2014 and January 2015. Vertical B-mode ultrasonography movies of IJV were recorded at five timepoints during blood donation: before donation, during donation, end of donation, end of fluid replacement, and after hemostasis. Cardiac variation of the IJV area and circumference were objectively measured using an automated extraction program together with blood pressure and heart rate. RESULTS: A total of 140 patients were screened, and data from 104 patients were included in the final analyses. Among the variables analyzed, only collapse index area and collapse index circumference could detect both intravascular volume loss and response to fluid administration. CONCLUSIONS: Cardiac variation of IJV may be a reliable indicator of intravascular volume loss and response to fluid administration in hemorrhagic shock.


Assuntos
Transfusão de Sangue Autóloga , Hidratação , Veias Jugulares/fisiopatologia , Ressuscitação , Choque Hemorrágico , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Choque Hemorrágico/diagnóstico por imagem , Choque Hemorrágico/fisiopatologia , Choque Hemorrágico/terapia , Ultrassonografia
11.
Vascular ; 28(4): 396-404, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32228224

RESUMO

BACKGROUND AND OBJECTIVES: Wall shear stress plays a critical role in neointimal hyperplasia after stent implantation. It has been found that there is an inverse relation between wall shear stress and neointimal hyperplasia. This study hypothesized that the increase of arterial wall shear stress caused by arteriovenous fistula could reduce neointimal hyperplasia after stents implantation. METHODS AND RESULTS: Thirty-six male rabbits were randomly divided into three groups: STENT, rabbits received stent implantation into right common carotid artery; STENT/arteriovenous fistula, rabbits received stent implantation into right common carotid artery and carotid-jugular arteriovenous fistula; Control, rabbits received no treatment. After 21 days, stented common carotid artery specimens were harvested for histological staining and protein expression analysis. In STENT group, wall shear stress maintained at a low level from 43.2 to 48.9% of baseline. In STENT/arteriovenous fistula group, wall shear stress gradually increased to 86% over baseline. There was a more significant neointimal hyperplasia in group STENT compared with the STENT/arteriovenous fistula group (neointima area: 0.87 mm2 versus 0.19 mm2; neointima-to-media area ratio: 1.13 versus 0.18). Western blot analysis demonstrated that the protein level of endothelial nitric oxide synthase in STENT group was significantly lower than that in STENT/arteriovenous fistula group, but the protein levels of proliferating cell nuclear antigen, vascular cell adhesion molecule 1, phospho-p38 mitogen-activated protein kinase (Pp38), and phospho-c-Jun N-terminal kinase in STENT group were significantly higher than that in the STENT group. CONCLUSION: High wall shear stress caused by arteriovenous fistula as associated with the induction in neointimal hyperplasia after stent implantation. The underlying mechanisms may be related to modulating the expression and activation of endothelial nitric oxide synthase, vascular cell adhesion molecule 1, p38, and c-Jun N-terminal kinase.


Assuntos
Derivação Arteriovenosa Cirúrgica , Artéria Carótida Primitiva/cirurgia , Procedimentos Endovasculares/instrumentação , Veias Jugulares/cirurgia , Neointima , Animais , Artéria Carótida Primitiva/metabolismo , Artéria Carótida Primitiva/patologia , Artéria Carótida Primitiva/fisiopatologia , Procedimentos Endovasculares/efeitos adversos , Hiperplasia , Proteínas Quinases JNK Ativadas por Mitógeno/metabolismo , Veias Jugulares/fisiopatologia , Masculino , Modelos Animais , Óxido Nítrico Sintase Tipo III/metabolismo , Fosforilação , Antígeno Nuclear de Célula em Proliferação/metabolismo , Coelhos , Fluxo Sanguíneo Regional , Stents , Estresse Mecânico , Molécula 1 de Adesão de Célula Vascular/metabolismo , Proteínas Quinases p38 Ativadas por Mitógeno/metabolismo
12.
World Neurosurg ; 138: e712-e717, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32194272

RESUMO

INTRODUCTION: Pressure gradients across venous stenosis are used as a marker for physiologically significant narrowing in idiopathic intracranial hypertension. Performing such measurements under conscious sedation (CS) more likely reflects physiologic conditions, but can be uncomfortable, leading some operators to perform measurement under general anesthesia (GA), though this may not be equivalent. METHODS: We performed a retrospective analysis of patients who received endovascular transverse sinus stenting due to idiopathic intracranial hypertension between August 2013 and May 2017. Patients' demographics and anesthetic parameters were collected along with venous pressure measurements. RESULTS: We identified 15 patients (14 women). The mean (SD) age was 30.5 (9.0) years and the mean body mass index (SD) was 39.5 (9.6) kg/m2. After measurements during CS, GA was induced with propofol and maintained with a volatile anesthetic. The median [IQR; range] transverse sinus pressure gradient under CS was 18 [12, 25; 6-38] mmHg compared with 14 [8, 21; 3-26] mm Hg under GA. The median [IQR; range] pressure gradient change after initiation of GA was -3 [-12, 0; -22 to 9] mm Hg (P = 0.014). After correction for increases in internal jugular vein pressures associated with assumption of GA, the median [IQR; range] gradient change was -11 [-12.5, -5; -22 to 0] mm Hg (P < 0.001). CONCLUSIONS: The transition from CS to GA results in clinically meaningful reductions in transverse sinus gradients in idiopathic intracranial hypertension. Correction for increases in the internal jugular vein pressures reveals even more dramatic reductions in transverse sinus gradients.


Assuntos
Anestesia Geral/efeitos adversos , Pressão Venosa Central , Circulação Cerebrovascular , Stents , Seios Transversos/cirurgia , Adolescente , Adulto , Índice de Massa Corporal , Sedação Consciente , Procedimentos Endovasculares/métodos , Feminino , Humanos , Veias Jugulares/fisiopatologia , Masculino , Pseudotumor Cerebral/complicações , Pseudotumor Cerebral/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
13.
Vascular ; 28(4): 450-456, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32122275

RESUMO

OBJECTIVE: Pancreatic cancer is a kind of high malignant tumor with a poor prognosis. The aim is to determine whether the dilated bile duct can be used to reconstruct the vessels. METHODS: An animal model of jugular vein and portal vein reconstruction was established using the bile duct. A total of 20 landrace pigs were selected to undergo jugular vein reconstruction or portal vein reconstruction using the bile duct as a patch or bridge. The patency was evaluated by color Doppler, the reconstructed segments were removed and examined macroscopically and histologically at specified intervals, and the results were compared with synthetic vessels (IMPRA straight, 10s03-19). RESULTS: The lumen was patent, although a low level thrombosis was observed when jugular or portal vein patching was used. For bridging, stenosis of the lumen was observed, and necrosis appeared when the bile duct was used for bridging, indicating that it is feasible to reconstruct the jugular vein and portal vein with a bile duct patch. However, the bridge was not feasible possibly due to loss of blood supply, and consequent necrosis and fibrosis. CONCLUSION: The bile duct is technically feasible, but the outcomes are unsatisfactory.


Assuntos
Bioprótese , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Ducto Colédoco/transplante , Veias Jugulares/cirurgia , Pâncreas/cirurgia , Veia Porta/cirurgia , Animais , Implante de Prótese Vascular/efeitos adversos , Ducto Colédoco/patologia , Ducto Colédoco/fisiopatologia , Estudos de Viabilidade , Feminino , Fibrose , Sobrevivência de Enxerto , Veias Jugulares/patologia , Veias Jugulares/fisiopatologia , Masculino , Modelos Animais , Necrose , Veia Porta/patologia , Veia Porta/fisiopatologia , Sus scrofa , Fatores de Tempo , Grau de Desobstrução Vascular
14.
Eur Radiol ; 30(7): 3890-3899, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32157411

RESUMO

OBJECTIVES: To use multi-parametric magnetic resonance imaging (MRI) to test the hypothesis that hypertensives would have higher retrograde venous blood flow (RVBF) in the internal jugular veins (IJV) vs. normotensives, and that this would inversely correlate with arterial inflow and gray matter, white matter, and cerebrospinal fluid volumes. METHODS: Following local institutional review board approval and written consent, a prospective observational 3-T MRI study of 42 hypertensive patients (53 ± 2 years, BMI 28.2 ± 0.6 kg/m2, ambulatory daytime systolic BP 148 ± 2 mmHg, ambulatory daytime diastolic BP 101 ± 2 mmHg) and 35 normotensive patients (48 ± 2 years, BMI 25.2 ± 0.8 kg/m2, ambulatory daytime systolic BP 119 ± 3 mmHg, ambulatory daytime diastolic BP 90 ± 2 mmHg) was performed. Phase contrast imaging calculated percentage retrograde venous blood flow (%RVBF), brain segmentation estimated regional brain volumes from 3D T1-weighted images, and pseudo-continuous arterial spin labeling measured regional cerebral blood perfusion. Statistical analysis included two-sample equal variance Student's T tests, two-way analysis of variance with Tukey's post hoc correction, and permutation-based two-group general linear modeling (p < 0.05). RESULTS: In the left IJV, %RVBF was higher in hypertensives (6.1 ± 1.5%) vs. normotensives (1.1 ± 0.3%, p = 0.003). In hypertensives, there was an inverse relationship of %RVBF (permutation-based general linear modeling) to cerebral blood flow in several brain regions, including the left occipital pole and the cerebellar vermis (p < 0.01). Percentage retrograde flow in the left IJV correlated inversely with the total matter volume (gray plus white matter volume) in hypertensives (r = - 0.49, p = 0.004). CONCLUSION: RVBF in the left IJV is greater in hypertensives vs. normotensives and is linked to regional hypoperfusion and brain total matter volume. KEY POINTS: • Hypertensive humans have higher retrograde cerebral venous blood flow, associated with regional brain hypoperfusion and lower tissue volume, compared with controls. • Cerebral retrograde venous blood flow may add further stress to already hypoperfused tissue in hypertensive patients. • The amount of retrograde venous blood flow in hypertensive patients may predict which patients might be at higher risk of developing cerebral pathologies.


Assuntos
Artérias Cerebrais/fisiopatologia , Hipertensão/fisiopatologia , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Circulação Cerebrovascular/fisiologia , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Marcadores de Spin
15.
Neuroradiology ; 62(4): 447-454, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31898766

RESUMO

PURPOSE: Previous studies have shown that arterial spin-labeling (ASL) has high sensitivity and specificity for detecting dural arteriovenous fistulas (DAVFs). However, in case of jugular venous reflux (JVR), the labeled protons in the jugular vein may lead to a venous hypersignal in the jugular vein, sigmoid, and transverse sinus on ASL images and mimic DAVF. METHODS: To ascertain this hypothesis, two blinded senior neuroradiologists independently and retrospectively reviewed randomized ASL images and graded the likelihood of DAVF on a 5-point Likert scale in 2 groups of patients: (i) 13 patients with angiographically proven type I DAVF; and (ii) 11 patients with typical JVR diagnosed on the basis of clinical and MR imaging data, first using ASL alone, and second using ASL together with all of the sequences including 4D CE MRA. RESULT: A dural venous ASL signal was seen in 11 patients with type I DAVF and in all the 11 patients with JVR, with no distinctive pattern between the two. The mean Likert score was "very likely" in DAVF and JVR patients when using ASL alone (k = 0.71), and "very unlikely" for JVR versus "very likely" for DAVF when using all the sequences available (k = 0.92). CONCLUSION: Our study shows that JVR can mimic DAVF on ASL images with potential implications for patient care. The detection of DAVFs should be based on additional MR sequences such as TOF-MRA and 4D CE MRA to exclude JVR and to avoid unnecessary DSAs.


Assuntos
Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/fisiopatologia , Angiografia por Ressonância Magnética/métodos , Idoso , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Estudos Retrospectivos , Sensibilidade e Especificidade , Marcadores de Spin
16.
Ann Vasc Surg ; 64: 303-317, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31394214

RESUMO

BACKGROUND: Vein graft (VG) failure due to neointimal hyperplasia remains an important and unresolved problem in cardiovascular surgery. Sirtuin3 (SIRT3) is associated with oxidative stress and lifespan. We aimed to measure SIRT3 expression in the veins of humans and rats during aging, explore the inhibitory effects of SIRT3 on vascular smooth muscle cell (VSMC) proliferation and neointimal hyperplasia in VGs, and investigate the underlying mechanisms. METHODS: SIRT3 mRNA and protein levels in saphenous veins of young and older humans and in veins of young and old rats were measured by quantitative real-time polymerized chain reaction (PCR) and Western blot analysis. Young and old male rats were randomized to the control (control), graft (graft), adenovirus-encoding green fluorescent protein (Ad-GFP), and adenovirus encoding SIRT3 (Ad-SIRT3) groups. At 7 days after operation, the mRNA and protein levels of SIRT3 and endothelial nitric oxide synthase (eNOS) were measured by quantitative real-time PCR and Western blot analysis. The mRNA levels and enzyme activity of manganese superoxide dismutase (MnSOD) and catalase (CAT) were measured by quantitative real-time PCR and enzymatic activity assay kits, and total nitric oxide (NO) levels were measured by biochemical assay kits. Histomorphometric analysis of VGs and immunohistochemical staining for proliferative activity were performed at 4 weeks after operation. The hemodynamic parameters of the VGs were also measured by ultrasonic examination. RESULTS: SIRT3 mRNA and protein levels were lower in older human and rat veins than in younger human and rat veins. Ad-SIRT3 treatment significantly increased the expression and concentration of SIRT3, MnSOD, CAT, eNOS, and NO in VGs at 7 days after operation. Ad-SIRT3 gene transfer reduced the neointimal thickness and neointimal area/media area ratio in the VGs of the Ad-SIRT3 groups compared with the graft and Ad-GFP groups, especially in old rats. Proliferative activity was lower in the Ad-SIRT3 groups than in the other groups. The hemodynamic parameters of VGs were obviously improved in the Ad-SIRT3 groups. CONCLUSIONS: SIRT3 expression decreases in the veins of humans and rats during aging. Furthermore, SIRT3 overexpression can significantly reduce VSMC proliferation and neointimal hyperplasia in VGs. Local intravenous delivery of adenovirus encoding SIRT3 may be a promising gene therapy for preventing VG failure.


Assuntos
Terapia Genética , Veias Jugulares/transplante , Neointima , Estresse Oxidativo , Sirtuínas/metabolismo , Fatores Etários , Animais , Artéria Carótida Primitiva/cirurgia , Proliferação de Células , Hemodinâmica , Humanos , Hiperplasia , Veias Jugulares/enzimologia , Veias Jugulares/patologia , Veias Jugulares/fisiopatologia , Masculino , Óxido Nítrico/metabolismo , Óxido Nítrico Sintase Tipo III/genética , Óxido Nítrico Sintase Tipo III/metabolismo , Ratos Sprague-Dawley , Sirtuína 3/genética , Sirtuína 3/metabolismo , Sirtuínas/genética , Fatores de Tempo , Regulação para Cima
17.
J Vasc Access ; 21(1): 98-102, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31232170

RESUMO

We are reporting a case of venous thoracic outlet syndrome with recurrent subclavian vein thrombosis in the setting of an ipsilateral brachiocephalic arteriovenous fistula for hemodialysis that was malfunctioning due to the central vein obstruction. The patient also had a concomitant external jugular vein origin stenosis. Given her body habitus and aversion to recovery after traditional first rib resection, we elected for an alternative treatment with an external jugular vein to internal jugular vein transposition with balloon angioplasty of the stenosed external jugular origin segment. The goal of this was to provide simultaneous relief of her outlet obstruction symptoms and salvage her dialysis access with a less invasive technique.


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Veias Jugulares/cirurgia , Falência Renal Crônica/terapia , Diálise Renal , Veia Subclávia , Síndrome do Desfiladeiro Torácico/terapia , Extremidade Superior/irrigação sanguínea , Enxerto Vascular/métodos , Adulto , Feminino , Humanos , Veias Jugulares/diagnóstico por imagem , Veias Jugulares/fisiopatologia , Veia Subclávia/diagnóstico por imagem , Veia Subclávia/fisiopatologia , Síndrome do Desfiladeiro Torácico/diagnóstico por imagem , Síndrome do Desfiladeiro Torácico/etiologia , Síndrome do Desfiladeiro Torácico/fisiopatologia , Resultado do Tratamento , Grau de Desobstrução Vascular , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/etiologia , Trombose Venosa/fisiopatologia
18.
Support Care Cancer ; 28(6): 2761-2768, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31724073

RESUMO

PURPOSE: Several studies have analyzed late complications associated with totally implantable venous access ports (TIVAP) implantation via the internal jugular vein (IJV); however, the reported results are inconclusive. The aim of the study is to elucidate the characteristics and risk factors of late complications associated with TIVAP implantation via the IJV. METHODS: The study included 482 patients who underwent TIVAP implantation for long-term chemotherapy and/or nutritional support between April 2012 and December 2017. Most patients (95.2%) had malignant diseases. Events requiring TIVAP removal were defined as TIVAP-related complications. RESULTS: The median TIVAP and global follow-ups were 319 days (IQR 152-661) and 218,971 catheter days, respectively. The 3-year cumulative TIVAP availability rate was 70%. There were 44 complications (incidence of 9.1%; 0.201 complications/1000 catheter days). Infectious, catheter-related, and port-related complications occurred in 21, 14, and 9 patients, respectively with infectious complications occurring earlier and more frequently than catheter- and port-related complications. Multivariate analysis revealed that age < 65 years and presence of non-gastrointestinal diseases were significant unfavorable factors for TIVAP-related complications. Patients with 1 and 2 of these factors had an elevated risk (2.2 and 5.4 times, respectively) compared with those without. CONCLUSIONS: Among the late complications associated with TIVAP implantation via the IJV, infectious complications occur earlier and more frequently than catheter- and port-related complications. Patients with an age < 65 years and having non-gastrointestinal diseases have a significantly high risk of TIVAP-related complications.


Assuntos
Infecções Relacionadas a Cateter/epidemiologia , Cateterismo Venoso Central/efeitos adversos , Cateteres de Demora/efeitos adversos , Cateteres Venosos Centrais/efeitos adversos , Veias Jugulares/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos/administração & dosagem , Antineoplásicos/uso terapêutico , Bactérias/classificação , Bactérias/isolamento & purificação , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Neoplasias/terapia , Adulto Jovem
19.
J Vasc Surg ; 72(1): 305-317.e6, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31699515

RESUMO

OBJECTIVE: The porcine arteriovenous graft model is commonly used to study hemodialysis vascular access failure, with most studies using a bilateral, paired-site approach in either the neck or femoral vessels. In humans, left- and right-sided central veins have different anatomy and diameters, and left-sided central vein catheters have worse outcomes. We assessed the effect of laterality on arteriovenous prosthetic graft patency and hypothesized that left-sided carotid-jugular arteriovenous prosthetic grafts have reduced patency in the porcine model. METHODS: Arteriovenous polytetrafluoroethylene grafts were placed ipsilaterally or bilaterally in 10 Yorkshire male pigs from the common carotid artery to the internal jugular vein. Ultrasound measurements of blood flow velocities and diameters were assessed before graft placement. Animals were sacrificed at 1 week, 2 weeks, or 3 weeks. Patency was determined clinically; grafts and perianastomotic vessels were excised and analyzed with histology and immunostaining. RESULTS: At baseline, left- and right-sided veins and arteries had similar blood flow velocities. Although internal jugular veins had similar diameters at baseline, left-sided carotid arteries had 11% smaller outer diameters (P = .0354). There were 10 left-sided and 8 right-sided polytetrafluoroethylene grafts placed; only 4 of 10 (40%) grafts were patent on the left compared with 7 of 8 (88%) grafts patent on the right (P = .04). Left-sided grafts had increased macrophages at the arterial anastomosis (P = .0007). Left-sided perianastomotic arteries had thicker walls (0.74 vs 0.60 mm; P = .0211) with increased intima-media area (1.14 vs 0.77 mm2; P = .0169) as well as a trend toward 38% smaller luminal diameter (1.6 vs 2.5 mm; P = .0668) and 20% smaller outer diameter (3.0 vs 3.7 mm; P = .0861). Left- and right-sided perianastomotic veins were similar histologically, but left-sided veins had decreased expression of phosphorylated endothelial nitric oxide synthase (P = .0032) and increased numbers of α-actin-positive smooth muscle cells (P = .0022). CONCLUSIONS: Left-sided arteriovenous grafts are associated with reduced short-term patency compared with right-sided grafts in the Yorkshire pig preclinical model of arteriovenous prosthetic grafts. Laterality must be considered in planning and interpreting surgical preclinical models.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Artéria Carótida Primitiva/cirurgia , Oclusão de Enxerto Vascular/etiologia , Veias Jugulares/cirurgia , Grau de Desobstrução Vascular , Animais , Derivação Arteriovenosa Cirúrgica/instrumentação , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Artéria Carótida Primitiva/patologia , Artéria Carótida Primitiva/fisiopatologia , Oclusão de Enxerto Vascular/patologia , Oclusão de Enxerto Vascular/fisiopatologia , Veias Jugulares/patologia , Veias Jugulares/fisiopatologia , Masculino , Modelos Animais , Politetrafluoretileno , Desenho de Prótese , Fatores de Risco , Sus scrofa , Fatores de Tempo
20.
Ann Vasc Surg ; 65: 17-24, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31712190

RESUMO

BACKGROUND: Venous resection during pancreaticoduodenectomy for the excision of pancreatic cancer allows for a more complete resection with negative margins, which increases survival. When the resected vein is greater than 3 cm, reconstruction with an interposition graft is recommended. However, consensus regarding the optimal venous conduit has not been reached. The objective of this study is to compare outcomes between the paneled saphenous vein graft (SVG) and internal jugular vein graft (IJVG) in portomesenteric venous reconstructions after pancreaticoduodenectomy. METHOD: A retrospective review was performed of patients undergoing pancreaticoduodenectomy requiring an interposition graft for venous reconstruction between 2011 and 2019. Patients were stratified based on the type of conduit used (paneled SVG or IJVG). Preoperative patient characteristics, reconstruction details, and postoperative outcomes including graft patency were recorded. RESULTS: During the study period, 18 patients met inclusion criteria (10 female, mean age: 63 years, age range: 41-82 years). Thirteen patients underwent reconstruction with paneled SVG and five with IJVG. Comparing SVG and IJVG groups, there were no significant differences in venous resection length, venous diameters at the resection margins, or splenic vein ligation rate. For the paneled SVG, the average length of harvested vein was 168 mm which rendered 3-paneled grafts with an average diameter of 12 mm. The time to complete the venous reconstructions did not differ between the two groups (SVG: 263+/-204 min, IJVG: 216+/-77 min, P = 0.63). There were five graft thrombosis, three in the SVG group (mean follow-up time of 17 months) and two in the IJVG group (mean follow-up time of 8 months). All but one of the graft thromboses occurred during the index hospitalization. There was one donor site seroma and wound dehiscence in the SVG group and none in the IJVG group. Hospital length of stay was longer for the IJVG group (IJVG: 15.2 days, SVG: 10.2 days, P = 0.03). However, in-hospital and late mortality did not differ between the groups. CONCLUSIONS: Paneled SVG and IJVG are both versatile and durable conduits for venous reconstruction after pancreaticoduodenectomy, able to accommodate a wide range of venous defects. In this small series, SVG has comparable outcomes to IJVG. Paneled SVG is a suitable alternative to IJVG for portomesenteric reconstruction.


Assuntos
Veias Jugulares/transplante , Neoplasias Pancreáticas/cirurgia , Pancreaticoduodenectomia , Veia Porta/cirurgia , Veia Safena/transplante , Veia Esplênica/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Veias Jugulares/fisiopatologia , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Neoplasias Pancreáticas/mortalidade , Neoplasias Pancreáticas/patologia , Pancreaticoduodenectomia/efeitos adversos , Pancreaticoduodenectomia/mortalidade , Veia Porta/patologia , Veia Porta/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Veia Safena/fisiopatologia , Veia Esplênica/patologia , Veia Esplênica/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Trombose Venosa/etiologia , Trombose Venosa/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...